Description:
Spectrum Composite Restorative Kit by Dentsply is a universal microhybrid composite designed for the restoration of both anterior and posterior teeth. It is formulated as a sub-micron hybrid composite, which means it contains particles of varying sizes to achieve optimal strength and aesthetics. Since its introduction, Spectrum has gained significant market success due to several key factors. Firstly, it offers a simple application process, making it user-friendly for dental professionals. The kit includes all the necessary components and instructions for seamless restoration procedures. Additionally, Spectrum provides superior aesthetics, meaning it creates restorations that closely resemble natural teeth. The composite material is available in various shades and opacities, allowing for precise color matching and a seamless blend with the patient’s existing dentition. Furthermore, Spectrum has a proven clinical performance record. It has undergone extensive testing and evaluation, demonstrating its durability, wear resistance, and long-term stability. This ensures that the restorations created with Spectrum are reliable and long-lasting.
INDICATION:
• Restorations of all cavity classes in anterior and posterior teeth.
Features:
- Versatile Application: The Spectrum composite is suitable for the restoration of both anterior and posterior teeth, making it a universal solution for various cavity classes.
- User-Friendly: The kit is designed to provide a simple application process, ensuring ease of use for dental professionals. It includes all the necessary components and clear instructions, streamlining the restoration procedure.
- Superior Aesthetics: Spectrum composite is formulated as a sub-micron hybrid composite, incorporating particles of varying sizes. This formulation helps achieve optimal strength and aesthetics, creating restorations that closely resemble natural teeth.
- Color Matching: The composite material is available in a range of shades and opacities, allowing for precise color matching with the patient’s existing dentition. This enables a seamless blend and enhances the overall aesthetic outcome.
- Clinical Performance: Spectrum has a proven clinical performance record. It has undergone extensive testing and evaluation to ensure durability, wear resistance, and long-term stability of the restorations. This reliability contributes to long-lasting results.
Key specifications:
COMPOSITION:
- TEGDMA
- Dimethacrylate
- Multifunctional polymethacrylate
- Camphorquinone
- Ethyl-4(dimethylamino)benzoate
- Butylated hydroxytoluene (BHT)
- UV stabilizer
- Barium-aluminium-borosilicate glass (mean particle size < 1 µm)
- Silanated barium-boron-fluoro-alumino-silicate glass (mean particle size < 1 µm)
- Highly dispersed silicon dioxide (particle size 10-20 nm)
- Fluorescent agent
- Iron oxide pigments • Titanium dioxide
Curing Light Intensity ≥ 500 mW/cm2
Shades/Increment/layer Curing time
A1; A2; A3; A3,5; B1; Incisal-B1; B2; C2; C3; D3 | 3 mm | 20 sec |
Opaque-A2; Opaque-A3,5; A4; B3; C4 | 2 mm | 20 sec |
Storage condition
Inadequate storage conditions may shorten the shelf life and may lead to malfunction of the product.
- Store at temperatures between 2 °C and 28 °C (35 °F and 82 °F).
- Keep out of direct sunlight and protect from moisture.
- Do not freeze.
- Do not use it after the expiration date.
- Store in a dry environment (< 80% relative humidity).
Differences between various types of composites
Microfills | Microhybrid | Nanohybrid | |
Particle size | 0.01 to 0.1 µm (agglomerated) | 1- 0.1- to 2-µm glass
2- 40-nm silica |
1- 0.1- to 2-µm glass or resin micro particles
2- ≤100-nm nanoparticles |
Clinical use | · Sub gingival lesions
· Smooth surfaces · Anterior aesthetic |
w.r.t (1) Moderate-stress areas requiring optimal polishability (Classes III, IV) | Wrt (1) Moderate-stress areas requiring optimal Polishability
w.r.t (2) (Classes III, IV) |
Advantages | · Simulates actual enamel surface
· Highest aesthetic level · Better wear properties than any other · High luster and hold their polish over time · Stain and plaque resistant · Highest reflective and refractive indices hence more realistic translucency |
· Simulate the dentin of natural tooth structure.
· Higher strength can be used as substructure under microfills enamel layer. · Most Opaque of the 3 composite types, also great for masking out unwanted color and achieving extreme color changes. |
· exhibit higher polishability
· better surface smoothness · lifelike opacious translucency |
Disadvantages | · Less strength than micro and nanohybrid
· Dec. water sorption |
· Less polishable
· More difficult to marginate, and will wear faster than microfill resins.
|
· donot hold their polish long as microfills but better than microhybrids
· More susceptible to plaque and staining over time. · Less biological compatible with gingival tissues
|
Indications | · Class III & class V | · Anterior and posterior restorations
· Can be used to fill the bulk of the tooth |
· posterior restorations
· veneering mandibular anteriors · building up incisal edges · class IV restoration · increasing cuspid rise · when the doctor wants to use only one material |
Warnings
The material contains methacrylates and polymerizable monomers which may be irritating to skin, eyes and oral mucosa and may cause allergic contact dermatitis in susceptible persons.
• Avoid eye contact. In case of contact with eyes rinse with plenty of water and seek medical attention.
• Avoid skin contact to prevent irritation and possible allergic response. In case of contact, reddish rashes may be seen on the skin. If contact with skin occurs, remove material with cotton and alcohol and wash thoroughly with soap and water. In case of skin sensitization or rash, discontinue use and seek medical attention.
• Avoid contact with oral soft tissues/mucosa to prevent inflammation. If accidental contact occurs, remove material from the tissues. Flush mucosa with plenty of water and expectorate/evacuate the water. If inflammation of mucosa persists, seek medical attention.
Precautions
- If refrigerated, allow material to reach room temperature prior to use.
- Use protective measures for the dental team and patients such as glasses and rubber dam in accordance with local best practice.
- Contact with saliva, blood and sulcus fluid during application may cause failure of the restoration. Use adequate isolation such as rubber dam.
- Tightly close syringes immediately after use. • The syringes cannot be reprocessed. To prevent syringes from exposure to spatter or spray of body fluids or contaminated hands it is mandatory that the syringe is handled offside the dental unit with clean/disinfected gloves. Discard the syringe if contaminated.
Interactions:
Do not use eugenol- or hydrogen peroxide-containing materials in conjunction with this product since they may interfere with the hardening of the product.
Packaging:
Reviews
There are no reviews yet.